FAM and Biotin End Labeled 23S 874bp Amplicon fragment NALFIA control DNA

$296.00

Dual-labeled positive control DNA for nucleic acid lateral flow. An 874 bp 23S rRNA amplicon end-labeled with biotin and FAM, functionally tested with the Attogene Universal Lateral Flow Assay Kit (AU2034-01). Made in the USA with free technical support.

  • Sufficient for 20 universal lateral flow control reactions using the AU2034-01 kit
- +
SKU: NA2032-01 Categories: , Tag:

The FAM and Biotin End-Labeled 23S Amplicon Fragment (NA2032) is a ready-made positive control DNA for nucleic acid lateral flow immunoassays (NALFIA). It is an 874 bp 23S rRNA amplicon from Microcystis aeruginosa, labeled with biotin on one end and FAM on the other, and functionally tested with the Attogene Universal Lateral Flow Assay Kit (AU2034-01). Each vial is enough for 20 control reactions.

Dual-labeled amplicons are the basis of universal lateral flow detection: the biotin end binds streptavidin-gold and the FAM end is captured on an anti-FAM test line. Because this control is a long, 874 bp product, it is a good stand-in when you are developing assays for larger tagged amplicons, and it lets you check strips, buffer and technique separately from your own PCR.

Key Features

  • Known-good positive control: functionally tested with the AU2034-01 universal lateral flow kit.
  • Dual end labels: 5′ biotin on the forward strand and 5′ FAM on the reverse strand.
  • Large amplicon: an 874 bp product for validating detection of longer tagged amplicons.
  • Sequence verified: Nanopore sequencing matched M. aeruginosa 23S rRNA references at up to 99.76%.
  • 20 control reactions: enough to check each new strip lot or run.
  • Made in the USA: fast shipping and free technical support from Attogene scientists.

What’s in the Kit

  • FAM and biotin end-labeled 874 bp 23S amplicon, sufficient for 20 control reactions with the AU2034-01 kit

The amplicon was produced with these labeled primers:

  • Forward primer: 5′-/5Biosg/AGGGGTAAAGCACTGTTTCG-3′
  • Reverse primer: 5′-/56-FAM/CCTTCTCCCGAAGTTACG-3′

Also needed (not included): universal lateral flow strips with an anti-FAM/FITC test line and streptavidin-gold, such as the Universal Lateral Flow Assay Kit, plus its running buffer.

Who It’s For

  • Labs developing PCR, LAMP, RPA or CRISPR assays with lateral flow readout
  • Users of the Attogene Universal Lateral Flow Assay Kit who need an extra positive control
  • Teams training staff on lateral flow technique
  • QC labs checking new strip and buffer lots

How to Use the 23S Amplicon Control DNA

  1. Prepare the sample: dilute the control in lateral flow running buffer as described in your lateral flow kit instructions.
  2. Run the strip: dip a universal lateral flow strip into the sample.
  3. Read the result: check for the test line and control line within the time stated in your kit instructions.
  4. Compare: run a buffer-only negative alongside to confirm a clean background.

How It Works and Reading Results

Streptavidin-gold binds the biotin end of the amplicon as the sample flows up the strip. The FAM end is captured by the anti-FAM test line, so a red test line forms only when a single DNA molecule carries both labels. The control line confirms the strip ran correctly. A visible test line and control line with this control, and only a control line with the buffer-only negative, show that the strips, buffer and technique are working.

Validation Data

The amplicon was gel purified and sequenced on a Nanopore MinION from Microcystis aeruginosa UTEX 2388. Results:

  • 99.76% match: Microcystis aeruginosa NIES-933 gene for 23S rRNA, partial sequence
  • 99.51% match: Microcystis aeruginosa UTEX LB 2388 23S ribosomal RNA gene, partial sequence

Sequence:

ATTTTTTTGTCCTCTACTGGTTCGGTGCTATGTAAAACGGGTGTTTAACCGTTTTCGCATTTATCGTGAAACGCTTTCGCGTTTTTCGTGCGCCGCTTCAAGCACTGTTTCGTAACTTCGGGAGAAGGAGTAGGGGTAAAGCACTGTTTCGCCGCGGGCTGGGAGACCGGTACCAAGGCGAGGCAAACTCTGAATACGGCTAAAAAAACTACCAGTGAGACGGTGGGGGATAAGCTTCATCGTCAAGAGGGAAACAGCCCAGACCACCAGCTAAGGTCCCCAAATGATAACTAAGTGAGAAAGGAGGTGGGAGTGCATTGACAACCAGGAGGTTTGCCTAGAAGCAGCAACCCTTAAAAGAGTGCGTAATAGCTCACTGGTCAAGCGCTCCTGCGCCGAAAATGAACGGGGCTAAGTTATCTACCGAAGCTGTGGACTACATTGTAGTGGTAGGGGAGCGTTCTATAGGGGGTGAAGCAGTAGCGGCAAGCAGCTGTGGACTCTATAGAAGTGAGAATGTCGGCTTAAGTAGCGAAAATGTGGGTGAGAATCCCACACCCCGAAACCCCAAGGTTTCCTCCCGCAAGGCTCGTCCGCGGAGGGTCAGTCAGGACCTAAGGCGAGGCTGAAAAGCGTAGTCGATGGACAACGGGTTAACATTCCCGTACCGATTAATGATTGTGCCGGAGAACGGAGAAGGTCAACGTCAGCTGGATGTTGGTTACCAGTGCAAGCAGTCGAGGCGATGAGAGGTGGCGAAAACACCAGGAGCTAAGACGCGAGTCCCACCTCCCACGGGAGGGAAGTGGCGTTGATCAAGCTTCCTAGAAAAGCCCGAACCACGTTAATCATTAATTGCCTGTACCCGAAACCGACACAGGTGGGGAAGTAGAGAATACTAAGGGGCGCGAGATAACTCTCTCTAAGGAACTCGGCAAAATGACCCCGTAACTG

Complete Your Lateral Flow Workflow

Frequently Asked Questions

Which strips does it work with?

It is functionally tested with the Attogene Universal Lateral Flow Assay Kit AU2034-01. It should work with any strip that captures FAM/FITC on the test line and detects biotin with streptavidin-gold.

How many tests does one vial run?

20 control reactions with the AU2034-01 kit.

Why use a long amplicon as a control?

An 874 bp product shows that your strips and buffer can detect larger tagged amplicons, not just short ones.

Does it contain live organisms?

No. It is purified, labeled DNA only.

Can I make more of it myself?

Yes. Amplify M. aeruginosa or other cyanobacterial DNA with the labeled primers listed above. The Universal 23S PCR Amplification Kit uses the same primer set without labels.

Can Attogene build a custom assay?

Yes. Attogene offers custom lateral flow development, from labeled amplicon design to finished test strips.

For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.