Attogene’s Universal Lateral Flow Assay Kit (anti-FAM/FITC Gold, AU2034-04/05/06) is a ready-to-use anti-FAM gold lateral flow kit for developing rapid dipstick tests for labeled DNA and RNA, including amplification products from PCR, LAMP and RPA. Each kit contains 100 pre-striped 4.5 mm dipsticks with 15 nm colloidal gold conjugated to an anti-FITC/FAM antibody, and is available in 2-, 3- and 4-line formats.
The strips arrive pre-striped, so you can test your labeled product right away. There is no need to stripe capture antibodies or buy striping equipment, making it a cost-effective way to screen labeling strategies and primers before custom strip development.
Key Features
- FAM-based reporter: 15 nm anti-FITC/FAM gold binds any FITC/FAM-labeled molecule; lines develop red-purple.
- Biotin, DIG and DNP capture lines: streptavidin, anti-digoxigenin and anti-DNP test lines, depending on format, plus a goat anti-mouse (GAM) control line.
- Multiplex up to 3 targets: the 4-line strip detects three targets at once.
- 100 tests per kit: dipsticks supplied in two desiccated canisters.
- RNase-free running buffer: 100 µL per test.
- Simple storage: dipsticks and running buffer at room temperature; control nucleic acids at 2–8 °C.
- Flexible readout: read by eye, by photograph or with a lateral flow reader.
Choose Your Format
Lines are listed from the dip end upward and are spaced 4.5 mm apart, center to center.
- AU2034-04, 2-line: T1 streptavidin (biotin) and GAM control. Detects FITC/FAM + biotin products.
- AU2034-05, 3-line: T1 streptavidin (biotin), T2 anti-Dig (DIG) and GAM control. Up to 2 targets.
- AU2034-06, 4-line: T1 anti-DNP (DNP), T2 streptavidin (biotin), T3 anti-Dig (DIG) and GAM control. Up to 3 targets.
What’s in the Kit
Each anti-FAM gold lateral flow kit includes:
- 100 lateral flow dipsticks (4.5 mm × 60 mm) in two desiccated canisters
- 12 mL Nucleic Acid Lateral Flow Running Buffer (RNase-free)
- 96-well plate plus 4 extra wells
- Positive control nucleic acids, 20 µL each: biotin-FITC/FAM (all formats), FITC/FAM-DIG (AU2034-05 and -06) and FITC/FAM-DNP (AU2034-06)
- Manual
You will also need: a timer, a pipettor and tips, a centrifuge for clearing samples, tubes or microtiter plates, and your molecule of interest labeled with FITC/FAM plus biotin, DIG or DNP.
Optional add-ons: 2X running buffer (10 mL), 200 µL control nucleic acids (biotin-FITC/FAM, FITC/FAM-DIG or FITC/FAM-DNP), and cassetted strips (CO2022-02, 100 cassettes). For bulk strips or custom line configurations, contact sales@attogene.com.
Who It’s For
This kit suits researchers and assay developers whose amplification chemistry already uses FAM-labeled primers or probes, or who want biotin available as a capture label rather than a reporter label. It is a practical tool for adding a visual endpoint to PCR, LAMP or RPA assays, comparing primer sets, and testing multiplex labeling schemes before committing to a custom strip.
How to Use the Anti-FAM Gold Lateral Flow Kit
- Add 100 µL of running buffer to a well of the 96-well plate.
- Add your sample. Start with 1–5 µL of labeled product and keep the volume below 15 µL.
- Set up controls: 5 µL of control oligonucleotide for the positive control, and buffer only for the negative control.
- Mix each well by pipetting up and down several times.
- Insert one dipstick per well with the arrows facing up.
- Incubate for 30 minutes, then read by eye, by photograph or with a lateral flow reader.
Line positions, troubleshooting and design guidance are in the AU2034-04/05/06 kit manual (PDF).
How It Works and Reading Results
Every molecule to be detected must carry two labels: FITC/FAM, which binds the gold, and one capture label (biotin, DIG or DNP), which binds a test line. For amplification, label the 5′ end of one primer with FITC/FAM and the 5′ end of the opposite primer with the capture label, so every full-length product carries both. In multiplex formats, each target carries FITC/FAM plus its own capture label and develops at its own test line.
- Test line present: labeled product detected. Intensity rises with the amount of product compared with the negative control strip.
- Control line fading: expected. The GAM control captures gold that passes the test lines, so it weakens as the test line strengthens.
- No test line with a strong sample: possible hook effect. A serial dilution may bring the product into the working range.
Frequently Asked Questions
How is this different from the Strep-Gold version?
The anti-FAM gold lateral flow kit uses anti-FITC/FAM gold as the reporter and streptavidin, anti-DIG and anti-DNP as capture lines. The Strep-Gold universal kit reverses this, using streptavidin gold with anti-FITC/FAM, anti-DIG and anti-DNP capture lines. Choose the one that matches your primer labels.
What labels does my product need?
FITC/FAM plus one of biotin, DIG or DNP on the same molecule. A product with only one label will not form a test line.
What is the read time?
Read at 30 minutes unless your application shows that a different read time is optimal. Positive control lines appear within 15 minutes.
Can it detect multiple targets?
Yes. The 3-line format detects up to 2 targets and the 4-line format up to 3, with each target given its own capture label.
Can I get the strips in cassettes?
Yes. Cassetted strips (CO2022-02) can be ordered as an add-on with the anti-FAM gold lateral flow kit. For a fluorescent readout, see the fluorescent universal kit.
Can Attogene develop a custom test?
Yes. Our lateral flow development services can turn your feasibility results into a custom strip or cassette. You can also build your own strips with blank 4.5 mm lateral flow strips.
For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.