,

Streptavidin Coated ELISA Plates

Price range: $172.00 through $548.00

- +
SKU: EL2055 Categories: ,

Attogene streptavidin coated ELISA plates provide a pre-blocked, biotin-binding surface for a wide range of ELISA and assay procedures. Each well is coated with 300 ng of enhanced streptavidin, with an approximate binding capacity of 5 pmol biotin per well, and blocked with nuclease-free BSA. The plates capture biotinylated capture oligonucleotides, antibodies, peptide antigens, small molecules and other analytes without plate coating or blocking on your part.

The plates are polystyrene, 96-well strip plates with breakable wells and are offered in 5 Pack and 20 Pack sizes (catalog number EL2055). Because the target is held through the biotin-streptavidin interaction rather than by direct adsorption, they are well suited to small hydrophilic molecules and peptides that bind poorly to bare polystyrene.

Key Features

  • High binding capacity: 300 ng per well of enhanced streptavidin, with an approximate capacity of 5 pmol biotin per well, for reliable results in biotinylated assays.
  • Gentle immobilization: Easy, gentle capture of biotin-containing conjugates without denaturing protein components.
  • Low nonspecific binding: Streptavidin’s low isoelectric point of 5 to 6 results in low nonspecific interactions and helps keep background down.
  • Nuclease-free blocking: Pre-blocked with nuclease-free BSA, so the plates can be used in RNA applications.
  • Ideal for difficult molecules: Useful for biotinylated peptides, small hydrophilic molecules, and targets or antibodies that are degraded by direct adsorption to polystyrene.
  • Breakable strip wells: Use only the wells you need for each run.
  • Ready to use: Pre-blocked and ready for immediate use, saving time in assay setup.

Specifications

Each order of streptavidin coated ELISA plates includes plates with these specifications:

  • Coating: Enhanced streptavidin, 300 ng per well
  • Binding capacity: Approximately 5 pmol biotin per well
  • Binding property: Standard capacity, affinity
  • Blocking: Nuclease-free BSA
  • Material: Polystyrene
  • Wells and format: 96 wells, strip plate with breakable wells
  • Pack sizes: 5 Pack or 20 Pack
  • Storage: Store at 4°C on receipt, in the provided resealable pouches with desiccant
  • Shipping: Room temperature

Quality control: All wells are clear, colorless and free of foreign matter and scratches. Plates are tested using a nucleic acid detection system: the average CV of each test plate must be 10% or less, the average signal-to-noise ratio 5 or greater, and the plate-to-plate CV 10% or less. See the streptavidin coated ELISA plates specification sheet for details.

Who It’s For

  • Assay developers using biotinylated capture antibodies, antigens or oligonucleotides
  • Researchers working with peptides or small molecules that adsorb poorly to standard polystyrene plates
  • Nucleic acid labs that need a nuclease-free capture surface for biotin-labeled DNA or RNA
  • Labs that want a consistent, pre-blocked plate instead of in-house coating and blocking

How to Use Streptavidin Coated ELISA Plates in Your Assay

No assay protocol is supplied with the plates, so reagent concentrations, volumes and incubation times should be optimized for your system. A typical capture workflow:

  1. Prepare strips. Break off the wells you need and return the rest to the resealable pouch with desiccant at 4°C.
  2. Capture the biotinylated reagent. Add your biotinylated antibody, peptide, oligonucleotide or small molecule conjugate, diluted in a suitable buffer, and incubate so it binds the streptavidin surface.
  3. Wash. Remove unbound reagent with your ELISA wash buffer.
  4. Add samples and standards. Incubate so the captured reagent can bind its target, then wash.
  5. Detect. Add an enzyme-labeled detection reagent, incubate and wash.
  6. Develop and read. Add substrate, stop the reaction if required, and read absorbance on a plate reader.

Free biotin competes for streptavidin binding sites, so remove excess unconjugated biotin after labeling and avoid biotin-containing buffers or media in the capture step.

How Biotin-Streptavidin Capture Works

Streptavidin binds biotin with very high affinity. Coating the plate with streptavidin turns any biotinylated molecule into a capture reagent: the biotin tag anchors it to the well while the rest of the molecule stays free to interact with your target. This oriented, indirect capture avoids the denaturation that can occur when proteins or small molecules are adsorbed directly onto polystyrene.

To confirm that an antibody or oligonucleotide is biotinylated before capture, our biotin (vitamin B7) quantification kits measure free biotin and biotin on labeled molecules. For hapten-labeled nucleic acids, see our anti-FITC coated ELISA plates, anti-DIG coated ELISA plates and the complete Universal Nucleic Acid ELISA Kit. For rabbit antibody capture, use our goat anti-rabbit coated ELISA plates, and to coat your own plates, start with the ELISA development starter kit.

Frequently Asked Questions

What can I capture on streptavidin coated ELISA plates?

Streptavidin coated ELISA plates capture biotinylated molecules, including capture oligonucleotides, antibodies, peptide antigens and small molecules.

What is the binding capacity?

Each well is coated with 300 ng of enhanced streptavidin, and the approximate binding capacity is 5 pmol biotin per well.

Can I use the plates for RNA work?

Yes. The plates are pre-blocked with nuclease-free BSA, which allows them to be used in RNA applications.

How should the plates be stored?

Store at 4°C upon receipt and keep plates in the provided resealable pouches with desiccant. The plates ship at room temperature.

Why use streptavidin capture instead of direct coating?

Some peptides, small hydrophilic molecules and antibodies bind poorly to polystyrene or are degraded by direct adsorption. Capturing them through a biotin tag on streptavidin coated ELISA plates keeps them intact and accessible.

For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.

Pack

5 Pack, 20 Pack

You may also like…

Shopping Cart