Attogene’s Universal Human IgG/IgM Lateral Flow Serology Kit (Gold, AU2044) is a universal human IgG IgM lateral flow assay kit for building rapid tests that detect human IgG and IgM antibodies against any antigen you can biotinylate, such as a viral antigen or an autoimmune antigen. The kit uses streptavidin colloidal gold to capture your biotinylated antigen, includes 50 lateral flow dipsticks, and generally gives results in 10–15 minutes.
Because the antigen is supplied by you, the same kit can be used to test feasibility for many different targets. There is no need to stripe capture antibodies and no expensive equipment is required.
Key Features
- Bring your own antigen: works with any antigen that can be biotinylated.
- IgG and IgM detection: separate human IgG and human IgM capture lines, with biotinylated human IgG and IgM controls included.
- Built-in run control: biotinylated rabbit IgG bound to the gold is captured at a goat anti-rabbit (GAR) control line to confirm the strip ran correctly.
- Fast readout: reaction generally complete in 10–15 minutes; read by eye, by photograph or with a lateral flow reader.
- No striping required: a cost-effective way to screen antigens before downstream lateral flow development.
- Simple storage: store the kit at 2–30 °C; keep strips sealed with desiccant until use.
What’s in the Kit
Each IgG/IgM lateral flow assay kit includes:
- 50 lateral flow dipsticks
- 10 mL assay running buffer
- 500 µL rabbit IgG colloidal gold (control line reagent)
- 30 µL biotin human IgG (IgG control)
- 30 µL biotin human IgM (IgM control)
- One 96-well plate
- Manual
You will also need: your biotinylated antigen(s); samples (human serum, plasma or a contrived sample such as humanized IgG); a centrifuge for clearing specimens; a pipettor and tips; tubes or microtiter plates; and phosphate buffered saline for diluting the antigen.
Who It’s For
Antibody tests are a common way to determine whether a person has been exposed to a pathogen, and they are also valuable for detecting autoantibodies associated with autoimmune disorders. This kit is intended for researchers and assay developers who have a candidate antigen and want to find out quickly whether it can support a lateral flow serology test, before investing in a custom strip.
How to Use the IgG IgM Lateral Flow Assay Kit
First, prepare a serial dilution of your biotinylated antigen in phosphate buffered saline (for example, 1 mg/mL to 1 µg/mL) and prepare your serum, plasma or contrived sample.
- Add 150 µL of running buffer to a well of the 96-well plate.
- Add the test line reagent: 1–10 µL of biotinylated antigen is a good starting point. For IgG or IgM line controls, use 10 µL of the biotin human IgG or IgM control instead.
- Add the control line reagent: 10 µL of biotinylated rabbit IgG bound gold (100 ng total).
- Add 1–10 µL of sample. Always run positive and negative control wells.
- Mix each well completely by pipetting up and down several times, then add the test strip.
- Incubate for 10–15 minutes and read by eye, by photograph or with a lateral flow reader.
See the AU2044 kit manual (PDF) for full details.
Optimization and Reading Results
The relative stoichiometry between the biotinylated antigen, the biotinylated rabbit IgG and the streptavidin gold is critical. The right amount of antigen depends on its purity and sequence; a standard curve can be used to find the best ratio, generally between 100 ng and 1 µg per test. When running a new assay, try large dilutions to find the dynamic range and keep added volumes below 15 µL where possible.
- Test lines: the more human IgG or IgM in the sample that reacts with your antigen, the stronger the test line compared with a strip run without sample.
- Control line: unlike nucleic acid kits, the GAR control line should not weaken as the test lines strengthen.
- No test line: because of the hook effect, a serial dilution may be needed to bring the antigen into the right ratio with the gold.
Frequently Asked Questions
Does the kit include an antigen?
No. You supply the biotinylated antigen. The kit provides the strips, gold control reagent, buffer and human IgG/IgM controls.
What samples can I test?
Human serum or plasma, or contrived samples such as humanized IgG.
How much antigen should I use?
Start with 1–10 µL of a diluted antigen series. The optimal amount is generally between 100 ng and 1 µg per test and should be confirmed with a standard curve.
Is the result quantitative?
The IgG/IgM lateral flow assay kit can support qualitative or quantitative test development. A lateral flow reader can be used to generate numerical readings.
Can I detect nucleic acids instead?
For labeled DNA and RNA, use the universal lateral flow assay kit (Strep-Gold) or the fluorescent universal kit.
Can Attogene develop a custom serology test?
Yes. Once your IgG IgM lateral flow assay kit results show feasibility, our lateral flow development services team can build a custom strip or cassette. To build strips in-house, see the lateral flow development starter kit.
For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.