Fluorescent Universal Human IgG/IgM Lateral Flow Serology Kit (Europium)

$323.00

Antibody tests are a method of choice to determine if a person has been exposed to a pathogen or not. They are also incredibly valuable in the detection of autoantibodies that can be found in human autoimmune disorders. In this test, a biotinylated antigen (User supplied) is mixed with a biotinylated rabbit IgG (bind to goat anti rabbit control line) and sample (human sera or plasma) is simply mixed into with the specially designed assay running buffer in a well of the supplied 96-well plate, mixed and is then added to the sample port of the cassette. Generally, the reaction is complete in 10-15 minutes. It is very important to note that the relative stoichiometry between the biotinylated antigen, biotinylated rabbit IgG added, and the streptavidin gold is critical for assay optimization. The appropriate concentration of biotinylated antigen to use with strips is dependent upon the purity and sequence and a standard curve can be used to determine the relative ratio (generally between 1ng-100ng per test). A positive control line (biotin-rabbit IgG) antibody will bind to the goat anti rabbit (GAR) line on the test to ensure the assay is running appropriately.

323323
Cassetted Strips
CO2022-02 lateral flow cassettes. The kit ships with bare dipsticks; add cassettes if you want your strips housed in a plastic cassette with a sample well and read window. Useful for easier handling, field testing, demos, or prototyping a finished test format.
$100.00

Bare lateral flow dipstick next to a CO2022-02 plastic lateral flow cassette with sample well and read window

Left: bare dipstick (included in kit). Right: CO2022-02 cassette (this add-on).

Addons Price: $0.00
Total Price: $323.00
- +

The Attogene Fluorescent Universal Human IgG/IgM Lateral Flow Serology Kit (Europium), AU2052, is a europium IgG/IgM lateral flow kit for developing rapid tests that detect human IgG and IgM antibodies against any antigen you can biotinylate, such as a viral antigen or an autoimmune antigen. Each kit includes 50 ready-to-use dipsticks, 15 mL of assay running buffer, biotinylated rabbit IgG for the control line, biotinylated human IgG and IgM controls, and a 96-well plate.

The strips use europium-dyed polystyrene beads conjugated to streptavidin (UV excitation 300 nm to 400 nm, emission 610 nm) to capture your biotinylated antigen. Results are read by eye with an ultraviolet flashlight or in a fluorescent strip reader. Fluorescent lateral flow assays have been described as 2 to 100 times more sensitive than gold-based tests.

Key Features

  • Bring your own antigen: Works with any user-supplied biotinylated antigen, so one strip format can be used to screen many targets.
  • Separate IgG and IgM lines: Anti-human IgG and anti-human IgM capture lines report each antibody class.
  • Built-in run control: Biotinylated rabbit IgG binds the goat anti-rabbit (GAR) control line to confirm the strip ran correctly.
  • Europium detection: Streptavidin europium beads with 610 nm emission for black light or reader-based reads.
  • No striping required: Capture lines are pre-sprayed, so there is no need to stripe capture antibodies.
  • Cost-effective feasibility testing: Screen antigens and conditions before investing in downstream lateral flow development.

What’s in the Europium IgG/IgM Lateral Flow Kit

Each europium IgG/IgM lateral flow kit includes:

  • 50 lateral flow dipsticks (room temperature)
  • 15 mL Assay Running Buffer (room temperature)
  • 250 µL Biotin Rabbit IgG, control line antigen at 1 ng/µL (refrigerate)
  • 15 µL Biotin Human IgG, IgG control (refrigerate)
  • 15 µL Biotin Human IgM, IgM control (refrigerate)
  • One 96-well plate and manual

Store the kit at 2 °C to 30 °C. Strips are packaged in a vial with desiccant; avoid leaving the vial open for long periods.

You will also need: your biotinylated antigen(s), samples (contrived sample, human serum or plasma), a centrifuge for preparing clear specimens, and a pipettor with tips.

Who It’s For

Antibody tests are a method of choice for determining whether a person has been exposed to a pathogen, and they are valuable for detecting autoantibodies found in human autoimmune disorders. This kit is built for research labs and assay developers who want to test the feasibility of a fluorescent serology lateral flow assay for a new antigen without building custom strips, especially groups that read europium labels on a fluorescent reader.

How to Use the Europium IgG IgM Lateral Flow Kit

First prepare serially diluted biotinylated antigen in phosphate buffered saline (for example 1 µg/mL to 1 ng/mL), and prepare your clinical research sample (human serum or plasma) or contrived sample (for example humanized IgG).

  1. Add 300 µL of Lateral Flow Running Buffer to a well of the 96-well plate.
  2. Add test line reagent: 1 to 5 µL of biotinylated antigen is a good starting point. On a first run, try large dilutions and keep the volume below 15 µL if possible. For IgG or IgM line controls, use 5 µL of the biotin human IgG or IgM control.
  3. Add control line reagent: 5 µL of biotinylated rabbit IgG (5 ng total).
  4. Add 1 to 10 µL of sample. Always run positive and negative control wells.
  5. Mix each well completely by pipetting, then place a strip in the well and run vertically.
  6. Incubate for a minimum of 30 minutes. If the test line is weak or non-specific reactivity is still visible, extend the incubation.
  7. Read by eye with a UV flashlight or photograph in a fluorescent strip reader.

Full instructions are in the AU2052 instruction booklet (PDF).

How It Works and Reading Results

Your biotinylated antigen binds the streptavidin europium conjugate. If the sample contains human antibodies that recognize the antigen, they are captured at the anti-human IgG and/or IgM test lines along with the fluorescent beads. Biotinylated rabbit IgG is captured at the GAR control line.

The higher the concentration of reactive human IgG or IgM, the brighter the test line compared with a strip run without sample. The control line intensity does not decrease as the test lines increase. Read at the recommended time, since line intensity can vary with drying time.

The balance between biotinylated antigen, biotinylated rabbit IgG and the europium conjugate is critical. The best antigen amount depends on its purity and is generally between 1 ng and 100 ng per test; a standard curve helps find it. If no test line appears, a serial dilution may be needed because of the hook effect.

Background reading: the universal serology technical article (PDF) shows the strip format detecting anti-La (SSB) autoantibodies, and the Lumos Leelu reader article (PDF) covers europium reader performance on Attogene universal strips.

Frequently Asked Questions

What antigen do I need to supply?

Any antigen that can be biotinylated, such as a viral protein, autoantigen or allergen. The europium IgG/IgM lateral flow kit does not include antigen.

How long does a run take?

Plan on at least 30 minutes of incubation, longer if test lines are weak or non-specific signal remains.

What samples can I test?

Human serum or plasma, or contrived samples such as humanized IgG. Start with 1 to 10 µL per well.

Are other readout versions available?

Yes. The quantum dot version uses a different fluorescent particle, and the Universal Human IgG/IgM Lateral Flow Assay Kit uses visible colloidal gold.

Can the europium IgG/IgM lateral flow kit be customized?

Yes. Contact Attogene about custom configurations, or see our custom lateral flow assay development services. For nucleic acid targets, see the europium Fluorescent Universal Lateral Flow Assay Kit.

For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.

You may also like…

Shopping Cart