Tetrodotoxin (TTX) Lateral Flow Detection Kit

$188.00

  • Rapid cassette based LFA test for detecting TTX in liquid samples
  • 10 cassettes
  • 5 Sample Dilution Tubes
  • 5 Negative Control Tubes
  • 10 Fixed Volume Pipettes
  • Detects 10 ppb and greater TTX in the sample
  • Cost effective
  • Minimal training required

 

 

188188
Sample Dilution Buffer
Optional extra sample buffer for this rapid test kit. Your kit already includes enough buffer for its tests; add a 5 or 10 pack if you need to dilute samples that read above the kit's range, re-run samples, or keep spare buffer on hand for field work.
$60.00
$100.00
Addons Price: $0.00
Total Price: $188.00
- +

The Tetrodotoxin (TTX) Lateral Flow Detection Kit is a rapid, single-use cassette tetrodotoxin test kit for screening water and tissue extracts in the lab. It screens for TTX at a visual level of 10 ppb (10 µg/L), detects down to about 1.5 ppb with a lateral flow reader, and gives a result in 15 minutes.

Each kit covers 5 samples. Every sample is run on two cassettes: one for the sample and one for its own negative control, read side by side.

Key Features

  • Screening level: 10 ppb TTX by eye; about 1.5 ppb with a lateral flow reader.
  • Results in 15 minutes: no instrument is needed for the visual result.
  • Competitive gold assay: colloidal gold conjugated to an anti-TTX monoclonal antibody, with a tetrodotoxin–BSA test line.
  • Built-in reference: a negative control is supplied for every sample.
  • Simple liquid handling: fixed-volume 75 µL pipettes are included, so no adjustable pipettor is needed.
  • Room-temperature storage: all components are stored at room temperature.

What’s in the Kit

Each tetrodotoxin test kit includes:

  • 10 TTX cassettes, each in a foil pouch with desiccant
  • 5 tubes of 10X Assay Running Buffer, 15 µL per tube
  • 5 tubes of Negative Control (1X running buffer, no TTX), 150 µL per tube
  • 5 mL Sample Dilution Solution, for diluting samples that interfere with the assay
  • 10 fixed-volume pipettes, 75 µL
  • 1 manual

You will also need: a timer, disposable gloves, a microcentrifuge to clear turbid samples or tissue extracts, clean tubes, clean sample collection bottles and a permanent marker. A TTX standard for a positive control is not supplied.

Add-on: extra Sample Dilution Buffer is available with your order in a 5-pack or 10-pack.

Who It’s For

This tetrodotoxin test kit is intended for research and screening, including:

  • Seafood safety and marine biotoxin research labs screening pufferfish, shellfish and clam extracts
  • Toxicology and environmental research groups working with water samples
  • Researchers studying TTX in gastrointestinal contents or plasma in a research setting
  • Assay developers who want a convenient basis for building a TTX lateral flow assay

For quantitative results across many samples, see the Tetrodotoxin ELISA Kit.

How to Use the Tetrodotoxin Test Kit

  1. Prepare the sample. Test water directly, centrifuging turbid samples. For tissue, prepare a homogenate extract (for example 1 g of tissue in 30 mL of water), then centrifuge or filter so the liquid is clear. If interference is suspected, pre-dilute in the Sample Dilution Solution.
  2. Set up. Bring all components and samples to room temperature. Lay two cassettes flat per sample and label them, for example NC and the sample name.
  3. Mix the sample with buffer. Tap down a 10X running buffer tube. Using a fixed-volume pipette, add 2 x 75 µL (150 µL) of sample and mix 3 times.
  4. Load the sample. Transfer 2 x 75 µL of the mixed sample to the sample port of the sample cassette.
  5. Load the negative control. With a new pipette, add 2 x 75 µL of Negative Control to the second cassette.
  6. Read at 15 minutes. Leave both cassettes flat and undisturbed, then read them side by side by eye or with a lateral flow reader.

Download the full Tetrodotoxin Lateral Flow Test manual (PDF).

Reading Your Results

This is a competitive assay: a weaker test line means more TTX. Always compare the sample cassette with its negative control.

  • Invalid: no control line on either cassette. Repeat with new cassettes.
  • Negative: the sample test line is as strong as or stronger than the negative control (below about 10 ppb).
  • Low positive: the sample test line is clearly weaker but visible (about 10 ppb and above).
  • Positive: the sample test line is much weaker or absent (high TTX).

With a reader, compare the T/C ratio of the sample with that of its negative control; a lower T/C means more TTX. For approximate concentrations, run TTX standards prepared in the same sample type alongside your samples.

About Tetrodotoxin

Tetrodotoxin is a potent neurotoxin best known from pufferfish, and also found in other animals such as some gastropods, newts and crabs. It is generally thought to be produced by symbiotic bacteria rather than by the host animal. TTX blocks voltage-gated sodium channels, stopping nerve signal conduction. Traditional detection relies on LC-MS or HPLC; a lateral flow screen helps prioritize which samples need that analysis.

Frequently Asked Questions

How sensitive is the tetrodotoxin test kit?

The visual screening level is 10 ppb (10 µg/L). With a lateral flow reader, the kit detects to about 1.5 ppb.

What samples can I test?

Water, pufferfish tissue, shellfish and clam tissue extracts, gastrointestinal contents and plasma, for research use. Tissue should be extracted and centrifuged before testing.

Does it detect TTX analogs or other toxins?

The antibody is highly specific for tetrodotoxin. Cross-reactivity with TTX analogs and other marine neurotoxins such as saxitoxin is still being characterized. Contact Attogene for current specificity data.

Are the results quantitative?

No. The tetrodotoxin test kit is a screening test. Confirm positive results by LC-MS/MS, ELISA or another conventional method.

Can I screen for other marine toxins?

Yes. See the Saxitoxin (PSP) Lateral Flow Kit and the Okadaic Acid (DSP) Lateral Flow Kit for Shellfish.

For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.