, ,

G-25 Micro Spin Desalting Columns 7K MWCO

Price range: $149.00 through $280.00

  • Rapid, simple, and reliable components for purification of protein samples
  • Cleanup before or after antibody biotinylation
  • Prefilled with G25 Resin
  • Perfect for Desalting Protein
  • Made by Attogene in the USA

- +

G-25 Micro Spin Desalting Columns 7K MWCO (CO2027) are ready-to-use spin desalting columns for fast buffer exchange and cleanup of protein samples. Each 0.8 mL column has a 7 kDa molecular weight cutoff: proteins and other macromolecules above 7,000 MW pass through and are recovered, while more than 95% of salts and other small molecules under 1,000 MW are retained in the resin. Samples of 30 to 100 µL desalt in a 2-minute spin at 1,500 rcf.

The columns are made by Attogene in the USA, come prefilled and need no packing, and work even with very dilute samples of 25 µg/mL. They are sold in packs of 25 or 50 columns, each with a 20X azide-free PBS concentrate.

Key Features

  • 7 kDa cutoff: recovers proteins and macromolecules above 7,000 MW and retains salts and small molecules under 1,000 MW.
  • Fast spin protocol: 1-minute spins to prepare the column, then a 2-minute spin to collect the sample, all at 1,500 rcf.
  • Small sample volumes: load 30 to 100 µL per column.
  • Works with dilute samples: expected purification even at 25 µg/mL.
  • Simple format: polypropylene columns with a break-away bottom tab that fit standard 1.5 mL or 2.0 mL microcentrifuge tubes.
  • Biotinylation ready: suited to cleanup before or after antibody biotinylation.

Specifications

Each order of spin desalting columns includes:

  • Desalting columns: 25 columns (C02027-01-25) or 50 columns (C02027-01-50)
  • 20X Azide Free PBS: 15 mL

Column specifications:

  • Column size: 0.8 mL micro spin column
  • Resin: size-exclusion resin, prefilled
  • Molecular weight cutoff: 7.0 kDa
  • Sample volume: 30 to 100 µL; add a 15 µL stacker for samples under 70 µL
  • Salt retention: greater than 95% for salts and small molecules under 1,000 MW
  • Column material: polypropylene, with break-away bottom tab
  • Centrifugation: 1,500 rcf
  • Storage: columns and the 20X PBS at 2–8 °C

You will also need: 1.5 mL or 2.0 mL microcentrifuge tubes, a variable-speed microcentrifuge, an equilibration buffer such as PBS without preservative or HEPES, and ultrapure water or buffer for the stacker.

Who It’s For

These columns suit protein chemists, assay developers and lateral flow teams who need to move small protein samples into a new buffer or strip out salts, preservatives and unreacted labels. A common use is antibody labeling: exchange the antibody out of an amine or azide-containing buffer before labeling, then remove free label afterward. The Protein Biotinylation Kit uses the same spin format for both steps.

How to Use Spin Desalting Columns in Your Workflow

  1. Open the column: snap off the break-away tab at the bottom and loosen the top cap.
  2. Remove the storage solution: place the column in a 1.5 or 2 mL tube and spin for 1 minute at 1,500 rcf. Discard the flow-through.
  3. Equilibrate: add 300 µL of equilibration buffer to the top of the resin and spin for 1 minute at 1,500 rcf. Repeat for three washes in total.
  4. Mark the column: mark the side where the resin slants upward and keep that mark facing outward in every later spin. Incorrect orientation reduces desalting efficiency.
  5. Load the sample: move the column to a new tube and apply 30 to 100 µL of sample directly to the top of the resin bed. For samples under 70 µL, add a 15 µL stacker of ultrapure water or buffer once the sample has absorbed.
  6. Collect: spin for 2 minutes at 1,500 rcf. The flow-through contains your desalted sample. Discard the column after use.

Download the CO2027 spec sheet (PDF) for the full protocol.

Tips for Best Recovery

  • Keep the sample within the 30 to 100 µL range. Small samples need the 15 µL stacker to push them through the bed.
  • Apply the sample to the resin, not the column wall.
  • Use a buffer without sodium azide or primary amines if the protein will be labeled next.
  • Pair the columns with Streptavidin Colloidal Gold or Streptavidin Coated ELISA Plates once your antibody is biotinylated.

Frequently Asked Questions

What sample volume do the spin desalting columns accept?

Each column accepts 30 to 100 µL. For samples under 70 µL, add a 15 µL stacker after the sample absorbs into the resin.

What is the molecular weight cutoff?

The spin desalting columns have a 7.0 kDa cutoff. Proteins and macromolecules above 7,000 MW are recovered, and salts and small molecules under 1,000 MW are retained.

Can I reuse a column?

No. Discard each column after use.

How should I store the columns?

Store the columns and the 20X azide-free PBS at 2–8 °C.

Do the columns work with dilute samples?

Yes. Expected purification is possible even with very dilute samples of 25 µg/mL.

For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.

Size

25 columns, 50 columns

You may also like…

Shopping Cart