, ,

FITC/FAM Nucleic Acid Stoichiometry Lateral Flow QC Kit

$231.00

  • 50 Lateral Flow Dipsticks (4.5mm)
  • 10 mL Assay running buffer
  • 96 well plate
  • Oligonucleotide Controls (0.25uM-2.5uM)
- +

The FITC/FAM Nucleic Acid Stoichiometry Lateral Flow QC Kit (AU2063) is a nucleic acid lateral flow QC kit that checks whether a FITC- or FAM-labeled reaction product is within the working range of an anti-FAM/FITC gold lateral flow test. Each 3 mm dipstick has anti-FITC/FAM colloidal gold embedded in the sample/conjugate pad and a FAM-BSA test line in the center of the strip. Results are generally ready in 10 to 15 minutes.

The kit contains 50 dipsticks, 10 mL of nuclease-free running buffer, four FITC/FAM-labeled control oligonucleotides at defined concentrations and a 96-well plate. It is a companion product to Attogene’s anti-FAM/FITC gold Universal Lateral Flow strips (AU2034-04/05).

Key Features

  • Stoichiometry check: Shows how much FITC/FAM-labeled nucleic acid your sample contains relative to the anti-FITC/FAM gold, so you can add the right amount to your main assay.
  • Four-point control series: Control oligonucleotides at 0.5, 0.2, 0.12 and 0.05 µM (2.5, 1, 0.5 and 0.25 pmol per 5 µL) give a reference curve in every experiment.
  • Fast: Strips are read after a 15-minute incubation.
  • Ready to use: Gold conjugate and FAM-BSA test line are built into the strip; there is no need to stripe capture reagents and no expensive equipment is required.
  • Broad compatibility: Suitable for FITC/FAM-labeled amplification products from PCR, LAMP and RPA reactions.
  • Cost-effective: Verifies sample range before you commit material to downstream lateral flow assay development.

What’s in the Kit

Each nucleic acid lateral flow QC kit includes:

  • 3 mm lateral flow dipsticks: 50 each (room temperature)
  • Nuclease-free lateral flow running buffer: 10 mL (room temperature)
  • Control nucleic acid containing biotin and FITC/FAM, 0.5 µM (2.5 pmol/5 µL): 20 µL (refrigerate)
  • Control nucleic acid containing biotin and FITC/FAM, 0.2 µM (1 pmol/5 µL): 20 µL (refrigerate)
  • Control nucleic acid containing biotin and FITC/FAM, 0.12 µM (0.5 pmol/5 µL): 20 µL (refrigerate)
  • Control nucleic acid containing biotin and FITC/FAM, 0.05 µM (0.25 pmol/5 µL): 20 µL (refrigerate)
  • 96-well plate: 1
  • Manual: 1

You will also need: your FITC/FAM-labeled molecules of interest, a timer, a centrifuge for preparing clear specimens, a pipettor with tips, and tubes or microtiter plates for running strips. If you need to add larger sample volumes, ask about Attogene’s 2X nuclease-free sample running buffers.

Who It’s For

This kit is for researchers developing nucleic acid lateral flow assays who label amplification products with FITC or FAM, especially users of the anti-FAM/FITC gold Universal Lateral Flow strips. It helps assay developers and QC staff confirm that a sample falls within the expected concentration range before running it on a detection strip, and helps estimate how much sample to add.

How to Use the Nucleic Acid Lateral Flow QC Kit

  1. Add 100 µL of running buffer to a well of the 96-well plate for each strip.
  2. Set up your wells. Sample: mix 1 to 5 µL of product into the buffer as a starting point; try large dilutions on first use and keep the volume below 15 µL if possible. Positive controls (4 strips): add 5 µL of each control oligonucleotide to its own well. Negative control (1 strip): buffer only.
  3. Mix each well thoroughly by pipetting up and down several times.
  4. Add one dipstick to each well with the arrows facing up.
  5. Incubate for 15 minutes.
  6. Read the strips by eye, by photograph or with a lateral flow reader.

Complete instructions are in the AU2063 kit manual (PDF).

How the QC Strip Works and How to Read It

When a strip is placed in the well, the anti-FITC/FAM gold flows up the nitrocellulose. Gold that is not bound to FITC/FAM-labeled nucleic acid is captured by the FAM-BSA test line. Gold that is bound to labeled sample or standard flows past the test line to the wick. Because the labeled analyte competes with the FAM-BSA line for the same gold binding sites, the test line becomes weaker as more labeled nucleic acid is added.

Compare each sample with the buffer-only negative control strip, which shows the strongest line, and with the four control strips. A clear reduction in line intensity means the sample is saturating the gold. The controls should progressively eliminate the test line within 15 minutes at sufficiently high quantities. If you see no reduction as more control is added, or no line on the controls, check the kit expiration date. If no test line signal is detected in a sample, a serial dilution may be needed to bring it into range.

The test is semi-quantitative. The controls are a general reference only and should not be used to quantify your analyte; use methods such as acrylamide gels, HPLC, absorbance or fluorescence for accurate concentrations.

Using QC Results with Your Detection Assay

Data from this kit can be used to estimate how much sample to add when running Attogene’s Universal Lateral Flow Assay Kit (anti-FAM/FITC Gold). If you are working with biotin-labeled barcode targets, see the NALF Barcode Test Strips, and for custom strip architectures contact our lateral flow assay development services team.

Frequently Asked Questions

What does the nucleic acid lateral flow QC kit measure?

It shows whether the amount of FITC/FAM-labeled nucleic acid in your sample is within range of the anti-FITC/FAM gold, based on how much the FAM-BSA test line is reduced.

Why does the test line get weaker with more sample?

Labeled nucleic acid binds the gold and prevents it from binding the FAM-BSA line, so the line fades as the sample saturates the system. This competitive readout is expected.

Can I use it to quantify my product?

No. The nucleic acid lateral flow QC kit is semi-quantitative. Use gel, HPLC, absorbance or fluorescence methods for accurate concentrations.

How long does the test take?

The reaction is generally complete in 10 to 15 minutes; the manual specifies a 15-minute incubation before reading.

How should the kit be stored?

Store the kit between 2 and 30 °C, keep strips in the sealed pouch until use, and refrigerate the control nucleic acids.

For research use only. Not for use in diagnostic procedures. Questions? Call 512-333-1330 or email sales@attogene.com.

Attogene Universal Lateral Flow Assay Kits are a convenient ready-to-use kit for quick and cost-effective development of a lateral flow dipstick assay for detection of DNA and RNA products.

Inquire about custom configurations: sales@attogene.com

You may also like…

Shopping Cart